4 ton 410a piston size

3/8 80 (24.4) 35 (10.7) vertical or 80 (24.4) total 80 (24.4) For Heat Pump systems, the chart below shows when an application is considered Long Line. HP WITH R−410A REFRIGERANT LONG LINE DESCRIPTION ft (m) Beyond these lengths, long line accessories are required Liquid Line Size Units On Same Level Outdoor Below Indoor Outdoor Above Indoor

4 ton 410a piston size. R-22 R-410A Florator Piston for 60 (Piston Size 93) All Air Handler Model. Cat # : 17N36. Model/Part # : 10000047. Sign in for pricing and availability. Print. Quantity: Add to Cart. Save to List.

Installed a Goodman 410a condenser on a r22 evap. Coil do i just change out the piston on txv valve. (57) … read more. Phil. Consultant to Engrs, Govt... Degree, Mech Engr Techno... 13,205 satisfied customers. Just installed 2 new goodman 3.5 ton systems. On startup the. Just installed 2 new goodman 3.5 ton systems.

20-ton product line has been designed for use only with R-410A and POE oil (check unit model number for specific refrigerant). R-410A is a high-pressure refrigerant that requires the other components of the system to be rated for R-410A. For compressor lubrication, the refrigerant requires POE oil.Compressor oil is needed in the air conditioning systems as lubricant and heat removal. Sealing of rotors and piston is another function of the oil. Expert Advice On Improving Your...MFH COIL AC PISTON .093 4-5T STD-HI EFF 13-15 SEER. ... PISTON .093 4-5T. -Product Detail. CMH48/60PM2M. MFH ... 410A Nom. Capacity (Tons) 4-5 Fits Furnace Width ( ...Product Overview. CH33 Indoor Coils CH33-44/48B-2F. Minimal air resistance for better performance. 1.5 to 5-ton capacities. Cased. Horizontal configuration. Large-face area coil allows for high efficiency operation. Copper-rifled tubing and enhanced aluminum fins improve transfer. Long lasting, painted galvanized cabinet and plastic drain pans.goodman piston size. I bought some left over r22 goodman 13 seer condensor units. A gsc 2 ton and a 2 1/2 ton. Neither of these units had their customary piston connected to the condenser under the electrical panal. I decided to look online and get the piston size but under piston size for these 2 units just have a slash.

Brand New HEIL 2.5 Ton R-410A Piston Air Handler Multi-Position Aluminum 208/230/1 Model# FEM4P3000AL #BSP1 ... Refrigerant Type R-410A Liquid Line Size 3/8 in Suction Line Size 3/4 in Filter Size 16-3/8 x 21-1/2 in Motor Type ECM Motor Rating 1/3 hp Dimensions 49-5/8 in H x 17-5/8 in W x 22-1/16 in D ...Residential R-410A Split System Air Conditioners. ICP has evaluated the use of ¼” and c” liquid lines for R-410A refrigerant air conditioner. cooling-only systems. R-410A refrigerant lends itself well to the use of smaller liquid lines in. either retrofit applications with existing linesets, or new systems when cost saving is a.Lennox Elite CH35, CH35-51C-2F, 4 Ton, Piston (R410A), Cased Aluminum Horizontal Evaporator Coil. Cat # : 10C38. Model/Part # : CH35-51C-2F. Replacement Available This product has been replaced by Cat# Print. Quantity: Add …Piston r22 bitzer compressor r410a gas r507 25hp hermetic semi cylinder filling small r407c r404a r134aCylinder specifications Piston coil hvac 410a m099 438a tapatalkHvac piston size chart. R410a freon refrigerant 25lb tankSolved as shown in figure 2, a piston-cylinder assembly Solved 3-29 a piston-cylinder device contains 0.85 kg …None of the systems I retrofitted employed pistons after converting to 410A. The largest system I did was 5 ton. Some utilized pistons with 22 but I put in TXVs for 410A. Some others utilized TXVs with 22 and I just changed the TXV. These were all split system but I have seen some 7.5 ton 410A RTUs with pistons. New build though, not retrofitted.piston kit chart 4 pkcg-4001u april 2018 (*) signifies unit revision. (1) correct piston is supplied with the outdoor unit. (2) correct piston is supplied in the highest sales volume tested combination indoor unit. all other indoor combinations, piston must be purchased from distributor. (3) txv must be purchased separately.Nominal Capacity 2.5 ton. Flow Rate 1000 cfm. Power Source 208/230/1. Refrigerant Type R-410A. Liquid Line Size 3/8 in. Suction Line Size 3/4 in. Filter Size 16-3/8 x 21-1/2 in. Motor Type ECM. Motor Rating 1/3 hp. Dimensions 49-5/8 in H x 17-5/8 in W x 22-1/16 in D. Metering Device Piston

Technical Information. Suction Line Size—Evaporator to Compressor. 50 °F through 30 °F (145 through 99 psig) 29 °F through 10 °F (97 through 64 psig) 9 °F through –10 °F (62 through 38 psig) Suggested Allowable Pressure Drop in psig = 2 °F 4.6 lb (2 °F) 3.5 lb (2 °F) 2.5 lb (2 °F) Equivalent Suction Line Length—Feet System ...Qty. $239.00. Diversitech 3/8" Sight Glass Sweat for Air Conditioner Condenser View Item. Add To Cart. Qty. $32.95. The Goodman GSXN3N2410 is a 2 ton cooling-only condenser unit. Providing a 13.4 SEER2 efficiency with a single stage, reciprocating compressor, the GSXN3N2410 is an inexpensive condenser to cool your home when paired with an AC [email protected]. (888) 601–0038. Follow Us. General Features:The M4AC40 is fully charged from the factory. This unit is designed to operate at outdoor ambient temperatures as high as 115 °F. Cooling capacities are matched with air handlers and furnace coils that are AHRI certified. The unit is cert.Sep 12, 2013 ... Can you install a 410a condensing unit on a r22 system. Fast Affordable Air•150K views · 4:27. Go to channel · HVAC Service Call | Clogged ...Chrome/Firefox/Opera/Safari: If you're unhappy with Facebook's new small font size (or other annoyances), userscript Better Facebook gives you over 75 extra options with which you ...Contact Us. [email protected]. (888) 601–0038. Follow Us. Learn more. ADP 100000036 - Piston .53, 1 1/2 Ton R22, 2 Ton R410APiston Size 53. Can be used on 1 1/2 Ton R22 Coil or 2 Ton R410a Coil.

Jeff pegues spasmodic dysphonia.

Correction on reply # 15 - GSZ140481A piston size should be .078 not .080 Lessons learned the hard way.--Don't let brain think 13 SEER - R22 when working on 14 SEER -R410A -- Make sure new condenser has piston with it. Put piston chart in vehicle-carry it with me. rollandsaxton liked this post.4 TON AC/HP HORIZONTAL CASED "A" COIL, AIRFLOW:HORIZONTAL, CFM:1600, METERING DEVICE:PISTON, REFRIGERANT:R-410A(MUST CHANGE PISTON TO MAKE IT R-22), DESIGN PRESSURE:450 PSI, CONNECTION:3/8" X 7/8" SWEAT, DRAIN PAN:PLASTIC, DIMS:21"H X 21"W X 21 1/2"D, WEIGHT:43 LBS, IN BOX, MADE IN …Email a Friend. 888-341-7330. FIXED ORIFICE PISTON - R22 2.0T & R410A 2.5T - .059 OPENING - B1789859. piston kit chart 4 ppkcg-4001j february 2015 (*) signifies unit revision. (1) correct piston is supplied with the outdoor unit. (2) correct piston is supplied in the highest sales volume tested combination indoor unit. for all other indoor combinations, piston must be purchased from distributor. (3) txv must be purchased separately. piston kit chart 4 pkcg-4001u april 2018 (*) signifies unit revision. (1) correct piston is supplied with the outdoor unit. (2) correct piston is supplied in the highest sales volume tested combination indoor unit. all other indoor combinations, piston must be purchased from distributor. (3) txv must be purchased separately.

A 3.5-ton air-conditioning unit cools homes from 1,801 to 2,300 square feet, depending on location. The unit cools 1,801 to 2,100 square feet in southern states from Georgia to Cal...Chrome/Firefox/Opera/Safari: If you're unhappy with Facebook's new small font size (or other annoyances), userscript Better Facebook gives you over 75 extra options with which you ...Dimensions W H Suction Connection Liquid Connection ¾” Female NPT primary & secondary drain connections (Important: hand-tighten) 20⅛” 3” A 2.3” Specifications Model Dimensions Nominal Tons Connection Piston Size* Ship Weight W H A Liquid Suction (lbs) CAUF1824A6 13" 16¼" 13" 1½-2 ⅜" ¾" .059 18 CAUF1824B6 16½" 16⅛" 13" 1½-2 ...FIXED ORIFICE PISTON - R22 & R410A 3.0T - .068 OPENING - B1789868.14.4 kW Cabinet Size (MAX) 05 -­‐-­‐ ... TX2N4A Non-bleed Valve AC or HP R-410A 1½ - 2 Ton ... For a properly matched system and piston sizing information ...Goodman 4 Ton Fixed TXV Kit - R-410A. Model: TXV-48. $117.00. Add to Compare. Goodman 2 Ton Fixed TXV Kit - R-410A Refrigerant. Model: 0151R00209S. $120.00. Add to Compare. Goodman 5 Ton Fixed TXV Kit - R-410A Refrigerant. Model: 0151R00212S. $120.00. Add to Compare. Goodman 3 Ton Fixed TXV Kit - R-410A Refrigerant .Typical low pressure or suction side pressure for R410A is about 120 psi, varying by ambient temperature, here assuming 75°F, may vary by equipment and metering controls. 3. Typical high side pressure for R410A is < 600 psi at an ambient outdoor temperature of 95 °F, may vary by equipment. 4.Brand New HEIL 2.5 Ton R-410A Piston Air Handler Multi-Position Aluminum 208/230/1 Model# FEM4P3000AL #BSP1 ... Refrigerant Type R-410A Liquid Line Size 3/8 in Suction Line Size 3/4 in Filter Size 16-3/8 x 21-1/2 in Motor Type ECM Motor Rating 1/3 hp Dimensions 49-5/8 in H x 17-5/8 in W x 22-1/16 in D ...Installed a Goodman 410a condenser on a r22 evap. Coil do i just change out the piston on txv valve. (57) … read more. Phil. Consultant to Engrs, Govt... Degree, Mech Engr Techno... 13,205 satisfied customers. Just installed 2 new goodman 3.5 ton systems. On startup the. Just installed 2 new goodman 3.5 ton systems.048 = 4 Tons ... Check piston size shipped with indoor unit to see if it matches required indoor piston size. ... Table 4 – AC with R-410A Refrigerant Long Line ...

Page 1. June 2004. PISTON KIT CHART (cont'd) 2. AMANA PISTON KIT CHART VALUE LINE BAG ASSY PISTONS. Mix-Matched evaporators and Amana condensers will require piston changes as listed below: WARNING. IT IS ESSENTIAL THAT. INDOOR AND OUTDOOR SECTIONS BE PROPERLY MATCHED.

Mar 19, 2017 ... Orifice along with the safety, efficiency, and service procedures involved. I compare 4 major points of difference and how they affect the ...4 TON AC/HP HORIZONTAL CASED "A" COIL, AIRFLOW:HORIZONTAL, CFM:1600, METERING DEVICE:PISTON, REFRIGERANT:R-410A(MUST CHANGE PISTON TO MAKE IT R-22), DESIGN PRESSURE:450 PSI, CONNECTION:3/8" X 7/8" SWEAT, DRAIN PAN:PLASTIC, DIMS:21"H X 21"W X 21 1/2"D, WEIGHT:43 LBS, IN BOX, MADE IN …Rheem RH1T4821STANJA - 4 Ton, R410A, Single Stage, Aluminum Air Handler, Constant Torque Motor, 208/240V, 1 Ph, 60 Hz: Item Number: RH1T4821STANJA: Manufacturer Product Number: ... Drain Connection Size: 3/4" Suction Line Fitting: Sweat or Braze: Suction Line Size (OD) 7/8" Liquid Line Fitting: Sweat or Braze: Liquid Line Size (OD) …piston sizing is only a concern for heat pump heating operation. Follow piston change recommendations in this Guideline for proper heat pump heating operation (see Table …[email protected]. (888) 601–0038. Follow Us. General Features:The M4AC40 is fully charged from the factory. This unit is designed to operate at outdoor ambient temperatures as high as 115 °F. Cooling capacities are matched with air handlers and furnace coils that are AHRI certified. The unit is cert.York still ships an orifice with the condenser; And a schrader for the evap in you use said piston. There is no standard for piston sizing. Each mfr does it their own way. Nordyne uses a 67 for a 3 ton 410 unit for example. ADP says 73 for 3 ton R22. assembled, piped and wired at the factory to provide a single-piece. unit for shipment and rigging. Each unit is pressurized with a holding. charge of refrigerant R-410A for storage and/or shipping. The compact design, clean styling, small footprint, and quiet operation. make these condensing units and heat pumps suitable for almost any. Is your A/C System in need of repair or service? Get connected with the best heating and air conditioning contractors in your area. Call an AC Pro Certified contractor today for all …2 ton air charging chart 92 - 102337 - 01 - 00 55 outdoor ambient (°f db) 65 75 85 95 105 115 2 ton cooling - 13 and 14 seer system charge chart - refrigerant 410a pressure at suction service port (psig) connect pressure gauges to suction and liquid ports on unit. measure air temperature to outdoor coil.

Michigan news grand rapids.

Publix super market at hillwood shopping center.

*.Units are rated with 25 ft (7.6 m) of lineset length. See Vapor Line Sizing and Cooling Capacity Loss table when using other sizes and lengths of lineset. 3/4 3/4 3/4 7/8 7/8 7/8 1-1/8 Max Liquid Line† †.See Liquid Line Sizing For Cooling Only Systems with R-410A Refrigerant tables. 3/8 OUTDOOR UNIT SIZE FAN COIL PISTON SIZE BY OUTDOOR …None of the systems I retrofitted employed pistons after converting to 410A. The largest system I did was 5 ton. Some utilized pistons with 22 but I put in TXVs for 410A. Some others utilized TXVs with 22 and I just changed the TXV. These were all split system but I have seen some 7.5 ton 410A RTUs with pistons. New build though, not retrofitted.Nominal Capacity 2.5 ton. Flow Rate 1000 cfm. Power Source 208/230/1. Refrigerant Type R-410A. Liquid Line Size 3/8 in. Suction Line Size 3/4 in. Filter Size 16-3/8 x 21-1/2 in. Motor Type ECM. Motor Rating 1/3 hp. Dimensions 49-5/8 in H x 17-5/8 in W x 22-1/16 in D. Metering Device PistonSee the coil installation instructions for piston and TXV matches. 13 different models are available to suit a variety of situations and budgets ... 4 - 5 Ton Multi-Position Cased Evaporator Coil (21" W x 21" D x 30" H) Brand: ... Coil Size: 21"W x 30"H x 21"D. Ton: 5. 4. 4 to 5. Airflow: Upflow. Downflow. Horizontal. Refrigerant Type: R-410A ...These units use R-410A refrigerant which operates at 50 to 70% higher pressures than R-22. Use only R-410A approved service equipment. Refrigerant cylinders are painted a “Rose” color to indicate the type of refrigerant and may contain a “dip” tube to allow for charging of liquid refrigerant into the sys-tem.I just had a new condenser and evaporator installed, a Goodman model GSX130481BC 4 ton condenser and 4-5 ton Goodman model CHPF4860D6DB coil using R410A. The day after install, the system produced about a 14 degree F drop between the air intake and outlet vents.Chrome/Firefox/Opera/Safari: If you're unhappy with Facebook's new small font size (or other annoyances), userscript Better Facebook gives you over 75 extra options with which you ...Commercial 27.5 to 50 ton 60 hz, 22.9 to 41.7 ton 50 hz cv or vav rooftop air conditioners with reliatel controls, r-410a refrigerant (152 pages) Air Conditioner Trane Voyager YS 150–300 Installation, Operation And Maintenance Manual ... Page 21 Outdoor Unit Model Indoor Unit Model Piston Size(R410a) ... ….

100000042 ADP Piston - size 76 R410A (4 Ton) Abrpn: 100000042. Your No. This is non stock item. More Information. SKU. 104214. Default UOM.If you ask Concur’s Elena Donio what the biggest differentiator is between growth and stagnation for small to mid-sized businesses (SMBs) today, she can sum it up in two words. If ... assembled, piped and wired at the factory to provide a single-piece. unit for shipment and rigging. Each unit is pressurized with a holding. charge of refrigerant R-410A for storage and/or shipping. The compact design, clean styling, small footprint, and quiet operation. make these condensing units and heat pumps suitable for almost any. May 4, 2017 · A 0.067 orifice is about right for a 3 ton 13SEER R-410A system, or at least really close, depending on which manufacturers chart you look at. Generally you should ignore the orifice size listed on the indoor coil, and go with what the outdoor unit calls for, which in this case is a TXV. Mortex coils for manufactured housing are universal R22/R410a. The metering device (piston or TXV) is the key. It is common to replace a R22 condenser with a R410a condenser, keep the evap coil and change piston or TXV to match. The SEER on these suck when new. Disclaimer, I will only change out a manufactured house system if coil and condenser ...The range on flow rater piston of Goodman 2.5 ton condenser is from .059 to a .078 . Now if you needed a .059 and you put a .078 in it. It can flood back to get the compessor, also. Then vise versa it will starve the evaperator. You need to get the condenser model number and match it up to the evaperator coil model number or your …Hello, The cased "A" coil is a Model # TXCO49C4HPCO S/N Z0522LH5G made by American Standard. The 5 Ton condensor is made by Trane and it is Model # 2TTR1060A1000AA and S/N 5311T292F. I did remove the uncased coil from my air handler unit. It was in a housing that was mounted in front of the air handler.24ACC4: Product Data Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations. 5. Refrigerant Charge Adjustments. Units are factory charged for 15 ft (4.6 m) of 3/8” liquid line*. The factory charge for 3/8” lineset 9 oz. When using other length or diameter liquid lines ...It is measured in gallons per minute. 14*400= 5600.Multiply this answer with 500 5600*500 = 2,800,000.This is the equator size measured in BTUs per hour. Now divide this answer by 12,000, 2,800,000/12000. This is the correct value of evaporator size in tons. The evaporating coil sizing chart is very complicated to understand.Refrigerant Piping. DESIGN AND FABRICATION GUIDELINES. Corp. 9351−L9 Revised July 30, 2018. APPLICATION AND DESIGN GUIDELINES. Introduction. The piping design of any air conditioning system will affect the performance, reliability, and applied cost of that system. 4 ton 410a piston size, Be the first to ask a question about this product! Product Features. Product Details, According to Capital Home Builders, a 2,300-square-foot home needs a 4-ton air conditioner. Since there are 12,000 BTUs per ton, a house of this size needs a 48,000-BTU air conditi..., Residential Fan Coil; with standard features:ENVIRONMENTALLY SOUND R-410A SYSTEMSFactory installed piston metering device with Teflon ringHigh efficiency ECM, 5-speed motorCopper tube/aluminum fin coil on standard modelsAvailable with industry exclusive t , According to Capital Home Builders, a 2,300-square-foot home needs a 4-ton air conditioner. Since there are 12,000 BTUs per ton, a house of this size needs a 48,000-BTU air conditi..., Is your A/C System in need of repair or service? Get connected with the best heating and air conditioning contractors in your area. Call an AC Pro Certified contractor today for all …, I am installing a new cased coil Goodman CAPF36C6 WITH A NEW FURNACE GMVC95070 TWO STAGE 95% VS W. 4 TON blower. The old condenser is staying (Armstrong SCU1036). ... Goodman told me to use Armstrong's piston size. My concern is the 3 ton 13 SEER coil is twice the size of the OEM. ... Just gonna have to …, CAUF4860C6 20" 28" 25" 4-5 ⅜" ⅞" .093 48 CAUF4860D6 23" 28" 25" 4-5 ⅜" ⅞" .093 39 CAUF4961C6 20" 28" 25" 4-5 ⅜" ⅞" .093 54 CAUF4961D6 23" 27" 25" 4-5 ⅜" ⅞" .093 59 * Shipped with Coil Note: For a properly matched system and piston sizing information, refer to Goodman piston kit chart of the corresponding Goodman® outdoor unit. , Size (tons) Nominal BTU/hr Min. Circuit Ampacity Max. Fuse or Breaker Operating Dimensions ... 4 = R−410A REFRIGERANT A = Air Conditioner H = Heat Pump TYPE 3 = 13 SEER ... Check the piston size shipped with the indoor unit to see if it matches the required indoor piston size. If it does not match,, Wrong piston size for 15 year unit never ran right from the date of install www.amazon.com/shop/miheatingguyMilwaukee 2131-20 M18 ROCKET Dual Power Tower Lig..., Goodman 4 - 5 Ton, Cased Evaporator Coil (W 24-1/2 x D 21 x H 30) - Cased TXV Included. SKU: CAPT4961D4 Goodman, outdoor goodman indoor piston outdoor goodman indoor piston section indoor piston kit section indoor piston kit coil btu's size part no. coil btu's size part no. ckl18-1 18000 .052 (2) clj36-1 36000 .071 (2) 24000 .059 to .052 b17898-52 (3) 42000 .078 to .073 b17898-73 (1) 29000 .059 to .052 b17898-52 (3) 47000 .082 to .073 b17898-73 (1), Product Overview. CH33 Indoor Coils CH33-44/48B-2F. Minimal air resistance for better performance. 1.5 to 5-ton capacities. Cased. Horizontal configuration. Large-face area coil allows for high efficiency operation. Copper-rifled tubing and enhanced aluminum fins improve transfer. Long lasting, painted galvanized cabinet and plastic drain pans., Commercial 27.5 to 50 ton 60 hz, 22.9 to 41.7 ton 50 hz cv or vav rooftop air conditioners with reliatel controls, r-410a refrigerant (152 pages) Air Conditioner Trane Voyager YS 150–300 Installation, Operation And Maintenance Manual. ... See Table 1 for factory installed piston size. Some system combinations will require a different sized ..., 1 3/8. 1 5/8. 1 5/8. 1 5/8. Refer to DuPont Refrigerant Expert, Version 2.0 for actual velocities and pressure drops. Equivalent length is actual length plus friction losses caused by fittings and accessories. Line sizes are expressed in outside diameter of type “L” copper tubing. Line sizes are calculated at rated full load system capacity., ADP 100000039 - Piston .67, 2 1/2 Ton R22, 3 Ton R410APiston Size 67. Can be used on 2 1/2 Ton R22 Coil or 3 Ton R410a Coil. The store will not work correctly in the case when cookies are disabled. Due to scheduled maintenance, some website features will be unavailable on Saturday 10/29. ..., Mar 19, 2011 · Existing equipment is a 4 ton 10 seer r-22. If a 3.5 ton 14 seer 410a is installed in its place, does the seer make up for the 1/2 ton? … read more. , outdoor goodman indoor piston outdoor goodman indoor piston section indoor piston kit section indoor piston kit coil btu's size part no. coil btu's size part no. ckl18-1 18000 .052 (2) clj36-1 36000 .071 (2) 24000 .059 to .052 b17898-52 (3) 42000 .078 to .073 b17898-73 (1) 29000 .059 to .052 b17898-52 (3) 47000 .082 to .073 b17898-73 (1) , Get the lowest price on a 3.5 to 4 Ton Trane RunTru Evaporator Coil - 4MXCB006AC6HCA - Fast Delivery, ... Liquid Line Size: 3/8 inch : ... R-410a : Suction Line Size: 7/8 inch : Warranty: 5 Year Parts, 10 Year Evaporator Coil: California Residents: see Prop 65 WARNING: Accessories . Thermostats WE RECOMMEND., Dimensions W H Suction Connection Liquid Connection ¾” Female NPT primary & secondary drain connections (Important: hand-tighten) 20⅛” 3” A 2.3” Specifications Model Dimensions Nominal Tons Connection Piston Size* Ship Weight W H A Liquid Suction (lbs) CAUF1824A6 13" 16¼" 13" 1½-2 ⅜" ¾" .059 18 CAUF1824B6 16½" 16⅛" 13" 1½-2 ..., Testing Instruments. Manifolds and Gauges. ADP - 176799976 - 4 Ton Piston Size 76 R-22/R-410A. Advanced Distributor Products., Wrong piston size for 15 year unit never ran right from the date of install www.amazon.com/shop/miheatingguyMilwaukee 2131-20 M18 ROCKET Dual Power Tower Lig..., piston kit chart outdoor goodman indoor piston outdoor goodman indoor piston section indoor piston kit section indoor piston kit coil btu's size part no. coil btu's size part no. …, Product Description. Features. 10 year warranty on parts & compressor High efficiency scroll compressor. Direct drive multi-speed PSC indoor motor. All aluminum evaporator coil Designed for upflow, downflow, horizontal left and horizontal right installations. Condenser pre-charged with R-410A refrigerant. Insulated air handler cabinet., ADP - 176799976 - 4 Ton Piston Size 76 R-22/R-410A. Item: ADP176799976. MFG: 176799976. loading availability. Loading price. / EA. Skip to. Description. Features and …, Commercial 27.5 to 50 ton 60 hz, 22.9 to 41.7 ton 50 hz cv or vav rooftop air conditioners with reliatel controls, r-410a refrigerant (152 pages) Air Conditioner Trane Voyager YS 150–300 Installation, Operation And Maintenance Manual. ... See Table 1 for factory installed piston size. Some system combinations will require a different sized ..., The orifice will need to be changed. The question is whether the evaporator is rated for the 410 pressures. In the early days the R22 evaporators could not contain R410, but after 410 came out mfg’s started making heavier coils that could support 410 but R22 was cheaper and we had experience with it so we continued using it even though it …, 3 Ton Piston Size 73 R-22/R-410A . California residents: see Proposition 65 Warning. Features and Specification Weight: 2: Brand: Advanced Distributor Products: Composition: Copper: Connection Size: 3/8" Connection Type: Solder: Cubic Measurement: 0.1458: Height: 6: Inlet Connection Size: 3/8" Length: 7: Maximum Working Pressure:, Ton 410a. Goodman gsz13042 with same size goodman air handler - Answered by a verified HVAC Technician. We use cookies to give you the best possible experience on our website. ... Existing equipment is a 4 ton 10 seer r-22. If a 3.5 ton 14 seer 410a is installed in its place, ..., Thermostatic Expansion Valves can be mounted in any position on the evaporator coil inlet and are reliable, efficient and virtually trouble-free. Select the TXV to correspond with the tonnage of your air conditioner or heat pump, as well as to match the type of refrigerant your systems uses, R-22 (standard) or R-410A (new alternative)., Effective 4/1/10. Subject to change without notice. R22 (F) R410A (G) Tonnage Orifice Sz PART # Orifice Sz PART # 1.5T 0.055 3999 0.049 4006 2T 0.059 4000 0.055 3999 2.5T 0.068 3987 0.059 4000 3T 0.074 4001 0.068 3987 3.5T 0.080 3990 0.074 4001 4T 0.084 3991 0.080 3990 5T 0.092 3998 0.089 3960 Table 1: Piston Size- Non TXV use, 1048A16C 4 TON R22 CASED COIL 17.5" W/R410A PISTON. Sku#: 116614. Details. Air Conditioner Evaporator Coil; Item Coil; Size 17-1/2 Inch x 21-1/4 Inch x 20 Inch; Material Copper Alloy (Tubing); Used On Item Air Conditioner; Pressure Rating 2490 PSI; Refrigerant Type R-22; Coil Size 4 Ton. SPECIFICATIONS., According to my chart the GSZ14048 takes a .80 piston. Also Goodman does not ship the piston with the 14 SEER condensers. I guess they wanted to save a buck per unit since most have the option for TXV too. You definitely can not count on the correct piston being shipped in the AH or coil either., The duration of warranty coverage in Texas and Florida differs in some cases. At Goodman, we believe in American dependability. Units are designed, engineered and assembled in the U.S.A. Learn more about Goodman brand energy-efficient ARUE Series Air Handler - HVAC designed, engineered and assembled in the USA!