Running pressures for 410a

A strength test is considered a dangerous test (especially for R410a and other high pressure refrigerants) and all risks must be eliminated prior to starting work. 'The pressure in the system shall be built up gradually and monitored by remote calibrated gauge or other indicator located in a safe place.' ...

Running pressures for 410a. Still though... something doesn't sit well with me about all of it. I think I'm going to change the switch for good measure and reclaim/meter in the charge again. According to my PT chart, the static pressure of R410A at 65° is 185psi. I'm guessing that's not what you were asking about, but that's what it is.

Forum Rules. I have a 3Ton Carrier Heat Pump unit using 410A that has extremely high suction pressure around 250PSI. I also have a low liquid line pressure around 300PSI and my sub-cooling is around 40-50 Degrees. I have checked for a stuck liquid line solenoid but this system does not have one, and I checked the reversing valve and its ...

psig °f psig °f psig °f psig °f psig °f 12; –37.7. 114How to check the refrigerant level on a mini-split to see if you need to add additional refrigerant. Perhaps all you want to do is check your mini-split refr...R-410A Considerations: The IPR will open at a pressure 550 - 625 psig for R-410A systems. The high pressure switch opens at 610 psig ±. 10 psi g and cl oses at 500 psi g ± 15 psi g. The low pressure control will open at 50 psig. The discharge temperature of R-410A is lower than R-22 due to its higher vapor heat capacity.already running around the world has shown that there are signi˜cant bene˜ts for air conditioning units using R410A over other existing refrigerants mainly in terms of e˝ciency and reliability. Among its proven bene˜ts, air conditioning units using R410A have a higher cooling capacity and energy e˝ciency (EER) than units using R22 or R407C.A properly running A/C system with indoor and outdoor temperatures above 68 degrees will have a suction saturation above 32 degrees (freezing). ... (like a 440 PSI liquid pressure on an R410a system on a 90-degree day), do not proceed until you have further addressed the possible causes of high head, regardless of what the superheat or …The pressures were still at the 130 on suction side and 335 on the high side, but the cooling has gone away, suction side does not get cool. It has a metering orifice, no txv So, I thought I may be overcharged, since the liquid got in. I reclaimed some 410a (not measured) which sent the pressure too 150 on suction side and 365 on high side ...

If a well is running dry, the water pressure indoors may drop, and water may appear discolored. Use a probe to determine the depth of the water inside the well. Alternatively, Walk...This tends to be around 60 PSI to 85 PSI for R-22 and 105 PSI to 143 PSI for R-410A and is dependent upon operating conditions. What are normal operating pressures for 410A mini split? The low side pressure of a typical R410A mini split is between 110-140 psi depending on the operating conditions. However, it should not fall below 100 psi or ...Pressure Temp (°C) Temp (°F) Pressure Temp (°C) Temp (°F) Pressure Temp (°C) Created Date: 12/31/2018 2:21:34 PM ...Refrigerant Pressure - Temperature Chart. Pressure values are displayed for R-22, R-410a, R-407c, R-134a and R-404a refrigerants. Items Displayed in Red shows pressure in inches of Mercury. Items Displayed in Black shows pressure in pounds per inch gauge. Data points are reproduced based on available information.Originally Posted by EnergyOasis. I would like a little advice on what is best practices for coming upon a system that is moderately low (30degree evaporator) on 410a. My practices thus far for systems missing up to 20% of their charge is to soap Schraders/service valves, txv, inspect condenser coil & evaporator for signs of oil, and if nothing ...Online R454B pressure temperature chart spanning from -40°F to 150°F temp. Printable PDF version of R454B PT chart you can take with you on the job. There are several brand names for R454B: Opteon XL41, Solstice 454B, and Puron Advance. This is a blend of R32 (68.9%) and R1234yf (31.1%). It has a very low boiling point of -59.5°F (-50.9°C).

When heat is called suction and discharge pressures reach 300 + psi Compressor is running. Show More. Show Less. Ask Your Own HVAC Question. ... So, I decided too and some 410a. The pressures before energizing the unit were 170 lbs. on both sides. Upon energizing the unit the operating pressures were 75lbs on suction side and 250 on high side ...Use a pressure conversion chart to change the high side pressure to saturated temperature. Deduct the liquid-line temperature from the saturation temperature of R-410A refrigerant in the condenser to compute the sub-cooling value. On the manufacturer's data sheet find the correct operating pressures for the circumstances found for the ...Break the vacuum on the system and supply liquid R-410A to the liquid line or receiver port. Weigh in the initial charge and ensure a proper vacuum was achieved. Adjust sensors or set points to operate the compressor continuously while charging the system. Add refrigerant to allow the discharge pressure to rise to 325-420 psig.What is the higher pressure of R-410A? Normally R-22 operating system typically have a high-side (discharge) pressure of 260 psig and low-side (suction) pressure of 76 psig, while a normally R-410A operating system have a high-side (discharge) pressure of 418 psig and low-side (suction) pressure of 130 psig at 45°F/7.2℃.R-410a is designed to operate at higher pressures than R-22. If you use R-22 in the same system as R-410a, the compressor is going to be trying to work two different fluids through the same coils as both refrigerants respond differently to different mechanical situations. As you might imagine, this isn't going to go well for your air ...

La pulga online rio grande city.

As we will see in the R-22 and R-410A examples at the end, target superheat for a system using R-22 and the target superheat for a system using R-410A (or any other refrigerant) are the same. Only the DB and WB temperatures determine the target superheat. Here is the formula we use to calculate superheat: Target Superheat = (3 × TWet Bulb ...In contrast, R134A has been designed for smaller systems such as the automotive unit. R410A has a global warming potential of 1890, while R134A has a Global Warming Potential of 1340. Operating. R410A is a blend of two gases, R32 and R125. They developed it to replace R22 in home air-conditioning units.use on R-410A refrigerant systems. The low ambient . control pressure sensor is attached to the liquid line of the system, and monitors high side system pressure. Operation of the LAC occurs as outdoor temperatures drop below the 65°F to 50°F range. On/Off LAC operation cycles the condenser fan operation based on outdoor temperature.R32 is a single compound, while R410A is made from a mixture of R32 and R125. R410A has high pressure making it difficult to handle. R32 has higher cooling efficiency. In AC gas refilling, less R32 is required than R410A. R32 is moderately more flammable than R410A. What are the Advantages of Switching to R32. More efficient.compressor ZP42 (R410A) has been analyzed. 2 3 Pure Compressor Analysis: R410A and R407C show very similar performances with a slight advantage of R407C at higher pressure ratio, i.e. condition 2 and 3 in the above graphs. R410A compressors operate with a higher discharge temperature and therefore utilize unique engineering solutions to …

R-410A, sold under the trademarked names AZ-20, EcoFluor R410, Forane 410A, Genetron R410A, Puron, and Suva 410A, is a zeotropic but near-azeotropic mixture of difluoromethane (CH 2 F 2, called R-32) and pentafluoroethane (CHF 2 CF 3, called R-125) that is used as a refrigerant in air conditioning and heat pump applications. R-410A cylinders were colored rose but are no longer specially color ...10 Apr 2017 ... 7:41. Go to channel · R-22 and R-410A Operating Pressures on Air Conditioners! Checking the Charge! AC Service Tech LLC•459K views · 20:22. Go .....Refrigerant Pressure - Temperature Chart. Pressure values are displayed for R-22, R-410a, R-407c, R-134a and R-404a refrigerants. Items Displayed in Red shows pressure in inches of Mercury. Items Displayed in Black shows pressure in pounds per inch gauge. Data points are reproduced based on available information.Get it up to 200 and it would be grossly overcharged. It will be likely running in the 35 to 45f degree saturation (boiling point) range, 108 to 131 psi. The high side has an even greater range. The pressures will vary as the operating conditions like return air temperature, outdoor temperature change.Mar 16, 2024 · The purpose of the 410A PT Calculator is to accurately determine the pressure of R-410A refrigerant at various temperatures. Given the non-linear relationship between temperature and pressure for R-410A, the calculator provides a quick and accurate way to perform these calculations, essential for efficient HVAC system design, troubleshooting ... R-32 has only one-third of the GWP than R-410A, uses 20% less refrigerant, is easier to recycle, and is more efficient. These qualities make it an even more environmentally-friendly alternative for keeping your home comfortably cool. This refrigerant’s GWP is only 675, compared to R-22’s 1,810 GWP and R-410A’s 2,088 …R-404A began seeing usage in 1996 after the phase out of CFC R-502 due to it's Ozone Depletion Potential. R-404A is a ternary refrigerant blend consisting of the HFC R-125 (forty-four percent), HFC R-143a (fifty-two percent), and HFC R-134a (four percent). R-404A is used across a variety of low and medium temperature applications including ...Thoughts on R-454B. R-454B, or XL41, was invented and designed by the Chemours company as an alternative to R-410A applications. These applications include your traditional home air conditioners, your commercial air conditioners, heat pumps, and the occasional chiller. XL41 is a blended HFO refrigerant is comprised of sixty-eight point nine ...No, you cannot. To make a short story long, R410A and R22 are refrigerants. They are both good refrigerants and they both work, but they have to be charged in the system at different pressures. R410A is a higher pressure system and R22 is a lower pressure system. Putting them together would be like putting two cats in a box and sending them ...

very high condenser pressures compared to the R22 (R22: 43 °C, 15.8 bar; R410A: 42 °C, 26 bar) prevent the conversion of older sys-tems to R410A refrigerant. Because all components such as com-pressors, liquefiers, collectors, evaporators, piping, etc. must all be designed or developed to withstand these high pressures.

What is the standing and discharge pressure of a refrigerant? Refrigerant pressure readings R-22, R-410A, R-290, R-417A 1 Standing pressure – 150 PSI 2 Saction pressure – 60 TO 70 PSI 3 Discharge pressure – 250 TO 300. Freon gas standing and working pressure ( R32, R410A, R502,R407C, R134A etc )Digital Fieldpiece Gauges: https://amzn.to/2LFjNnKR410A Equipment: https://amzn.to/2xv6AG5My Favorite Tool: https://amzn.to/3NIFJuOTools We Recommend: https:...r410a running pressure chart. Free Printable 410A PT Chart Templates [PDF] High Altitude Calculator. ... What is the suction pressure of R410A in a Mitsubishi ton split A/C? Quora. Practice Checking the Charge of an R-410A Air Conditioner with Subcooling Method! Scenarios! In this HVAC Training Video, I show the R-22 and R-410A Range of Operating Pressures on Air Conditioning Systems! I show why we Measure Pressures and Tempera... A properly running A/C system with indoor and outdoor temperatures above 68 degrees will have a suction saturation above 32 degrees (freezing). ... (like a 440 PSI liquid pressure on an R410a system on a 90-degree day), do not proceed until you have further addressed the possible causes of high head, regardless of what the superheat or …No, you cannot. To make a short story long, R410A and R22 are refrigerants. They are both good refrigerants and they both work, but they have to be charged in the system at different pressures. R410A is a higher pressure system and R22 is a lower pressure system. Putting them together would be like putting two cats in a box and sending them ...AZ-20 (R-410A) pressure is about 60% (1.6 times) greater than R-22. Only use servicing equipment and components designed for AZ-20 (R-410A). - Recovery cylinder service pressure rating 400 psig, e.g. DOT 4BA400 and DOT BW400. - Manifold sets must be 800 psig high-side and 250 psig low-side with 550 psig low-side retard.

Quincy il breaking news.

Good morning happy thursday african american.

R-290's pressure drop in the theoretical application above (4.428 PSI/coil) is 49% lower than an identical coil running R-22 and 36% lower for the same coil running R-134a, resulting in reduced wattage consumption. R-290: Cons. The main drawback of R-290 is: Flammability classificationCans of R134a: https://amzn.to/3NLEJbr1/4" Can Adapters: https://amzn.to/3XKGL04New R1234yf Refrigerant: https://amzn.to/44xBxa3Gauges for Both Old & New Ref...Temperature and pressure chart for refrigerants R22, R410A, R12, R134A, R401A, R409A, R502, R404A, R507A, R408A and R402A.5 Refrigeration Troubleshooting Form. Download this manual. See also: Owner's Manual. INSTALLATION, OPERATION. & MAINTENANCE MANUAL. R-410A Water-to-Water Series: HWW Water-Source Heat Pumps. Heat Controller, Inc. • 1900 Wellworth Ave. • Jackson, MI 49203 • (517)787-2100 • www.heatcontroller.com. Table of Contents.In order to effectively flush R22 lines for 410A, it is recommended to remove the existing oil from the system. This is because R22 uses mineral oil, whereas 410A uses synthetic oil. Failure to remove the mineral oil can cause compatibility issues and affect the system’s performance. 3. Flushing R22 lines for 410A involves using a flushing ...In this video we go through the basics of checking a heat pump charge in heating. It can be tricky but its pretty simple if you do this..Title music:Music: B...R410A is a Hydrofluorocarbon (HFC ) Systems using R410A refrigerant run at a pressure of approximately 1.6 times that of similar systems using R22 and the energy efficiency is …compressor ZP42 (R410A) has been analyzed. 2 3 Pure Compressor Analysis: R410A and R407C show very similar performances with a slight advantage of R407C at higher pressure ratio, i.e. condition 2 and 3 in the above graphs. R410A compressors operate with a higher discharge temperature and therefore utilize unique engineering solutions to feature ... Online R454B pressure temperature chart spanning from -40°F to 150°F temp. Printable PDF version of R454B PT chart you can take with you on the job. There are several brand names for R454B: Opteon XL41, Solstice 454B, and Puron Advance. This is a blend of R32 (68.9%) and R1234yf (31.1%). It has a very low boiling point of -59.5°F (-50.9°C). R-410A. R-32. Formula. R-32 (68.9%) R-1234yf (31.1%) R-32 (50%) R-125 (50%) CH₂F₂. Molecular weight, (g/mol) 62.61. 72.6. 52. Boiling temp, ˚ F (˚ C)-58.9 ( … ….

Suction Pressure/EVAP DTD Rule of Thumb Another common old-school rule of thumb is that suction pressure should be close to the outdoor temperature in an R22 system. However, this rule of thumb (obviously) does not work on an R-410A system. A more applicable guideline is 20°-25° suction saturation below outdoor ambient.Step 19. Close the manifold and R-410 jug's valve handles. Disconnect the hoses and reinstall the caps on the service valve's ports. Advertisement. An azeotrope refrigerant blends multiple refrigerant compounds to form a single refrigerant. Most refrigerant blends boil at different rates and require complete evacuation before adding a full charge.R410A 4 K 0.9 1.5 K 3.5 K 8 K 8% 2% A/W HP Simulation with W35°C 0 0.5 1 1.5 2 2.5 3 ZP42 ZH12 ZHI11 ZH38 ZH13 Heating COP A/W HP Simulation with W55°C 0 0.5 1 1.5 2 …Let's get started and see what we can do.Most manufacturers recommend charging by super heat and subcoolimg rather than pressures alone,and will vary slightly by manufacturer but as a rule low side of about 110 and high side about 280at 70 degree ambient. This will of course increase as temp warms up.ON an 85 degree day,probably 130 to 135 and ...Daikin R-410A Manuals. Manuals and User Guides for Daikin R-410A. We have 35 Daikin R-410A manuals available for free PDF download: Service Manual, Installation Manual, Refrigerant Piping Design Manual, Technical Manual, Technical Data Manual, Owner's Manua, Installation Instructions Manual.Forum Rules. I have a 3Ton Carrier Heat Pump unit using 410A that has extremely high suction pressure around 250PSI. I also have a low liquid line pressure around 300PSI and my sub-cooling is around 40-50 Degrees. I have checked for a stuck liquid line solenoid but this system does not have one, and I checked the reversing valve and its ...Most technicians in the HVAC field know the normal range of operation for the low-pressure side of an air conditioning system. This tends to be around 60 PSI to 85 PSI for R-22 and 105 PSI to 143 PSI for R-410A and is dependent upon operating conditions. On the high-pressure side of the system, there is a wide variation in pressure due to the wide outdoor temperature swing and due to the ... Running pressures for 410a, When replacing an old R22 system with a new 410A system, it is important to flush the lines of any remaining debris and residue from the old refrigerant. This can be done by attaching a flushing device to your line set, connecting it to both suction and liquid lines, and running high pressure nitrogen gas through them., R-410A systems operate at higher pressures than standard R-22 systems. Do not use R-22 service equipment or components on R-410A equipment. Ensure service equipment is rated for R-410A.! WARNING Refrigeration systems contain refrigerant under pressure. Extreme caution should be observed when handling refrigerants. Wear safety glasses and gloves ... , Check the current low side pressure. A properly charged R410A mini split typically operates at about 110-140 psi in cooling mode and 250-400 psi in heat mode. ... In my past projects, we charge over thousands of mini splits based on the low side pressure and running amp. By doing so, we don't need to calculate the refrigerant pipe length and ..., 15 Feb 2024 ... What are the pressure differences between R410A, R32, and R454B? R410A, 434 psig R454B, 405 psig R32, 444 psig #hvac #hvactechnician #hvaclife # ..., I installed a new 410a complete system with new Orfice coil and new lineset. 70 degrees on install date and initial start up. Suction pressure was 110 and high side of 280. It ran for about 15 minutes. I added a little freon and the high side shot up to 425., The port sizes for R410A and R22 TXV's are basically identical, so they would each have the same flow capacity with either refrigerant . The difference is a R410A TXV will work properly with R22 only if you change out the R401A powerhead to one for R22. It'll then actually control superheat. The Educational Forums., i just installed a new split unit r-410a a/c system. it is running at 285/120 psig. the high side seems way low, should be about 420. the correct orifice is installed. …, The condenser comes charged with 15 feet of 410A. My install has 40 feet of 3/8" and 7/8" line total --- leaving 25 feet needing additional refrigerant. (Goodman suggest adding .6 oz per foot of liquid line) but that seems to be high. At the present time I am setting at 308 (High Side and 143 Low Side with no charge added beyond the 15 foot ..., Cooling Pressure (PSI) @ Service Port (Tolerance +/‐5) Outdoor Temp (°F) Refrigerant Pressure vs. Temperature Charts for Pioneer Split Systems (R410a) 68 115 119 123 127 131 135 139 143 147 71 120 124 128 132 136 140 144 148 152 ‐ m p (°F) 74 125 129 133 137 141 145 149 153 157, What is the standing and discharge pressure of a refrigerant? Refrigerant pressure readings R-22, R-410A, R-290, R-417A 1 Standing pressure – 150 PSI 2 Saction pressure – 60 TO 70 PSI 3 Discharge pressure – 250 TO 300. Freon gas standing and working pressure ( R32, R410A, R502,R407C, R134A etc ), The high side guage was connected to the liquid line. Static, both guages are 160 psig. When the unit ran, BOTH guages dropped to about 130. The high side was perhaps 2-5 higher. The amp draw at the compressor was 8.6 RLA out of a 22.1 suggest maximum on the equipment sticker., R-410A HFC 72.6-61 691.8 158.3 34.5 67.74 0.261 116.8 0.3948 0.1953 0 2088 A1 0.2 Refrigerant Reference Guide 43 5th Edition 2010 R-410A Technical Guidelines Applications: Air conditioning equipment and heat pumps. Only for newly manufactured equipment, not for retrofitting R-22 systems Performance: Presures are 60% higher than R-22, therefore ..., PROPERTIES R32 R410A Boiling point -51.7°C -51.0°C Critical temperature 78.4°C 72.0°C Saturation pressure at 4°C 818kPa 806kPa Saturation pressure at 40°C 2380kPa 2337kPa Global warming potential 675 2088 Flammability rating A2L lower flammability A1 non-flame propagation Note: R32 systems tend to have a smaller charge size than R410A., Not a dry charge he said he reclaimed the 410a and ran a vac on it, then installed 407c into the unit. I asked a lot of questions because I have never heard of such. The unit is a complete brand new unit 80% up flow,60,000 btu, 13 seer, 2.5 ton all matching goodman equipment. Reply. 05-14-2013, 12:38 PM #7., psig °f psig °f psig °f psig °f psig °f 12; -37.7. 114, Absolutely there is pressure in the air conditioning or heat pump system when the compressor is not running. When the compressor shuts off the high side pressure is high - say 200 and the low side low - say 20 (these are just conceptual as actual pressure depends on the compressor, ambient temperature, refrigerant type). , Make your job easier with our handy refrigerant pressure temperature HVAC app with R-410A included., Suction Pressure/EVAP DTD Rule of Thumb Another common old-school rule of thumb is that suction pressure should be close to the outdoor temperature in an R22 system. However, this rule of thumb (obviously) does not work on an R-410A system. A more applicable guideline is 20°-25° suction saturation below outdoor ambient., Fan pressure sw ., cut out / cut in, PSIG 190 - 240 High pressure cut out / cut in, PSIG 500 / 390 Compressor Amps, beg . - end, freeze 5 .8 - 5 .0 Compressor Amps, harvest 6 .8 Cycle Time (minutes) Ambient Air Temp (deg . F) Water Temp 70 80 90 50 13 13-14 17 70 13-14 14 17-18 80 14-15 15 19-20 90 15-16 17 21-22 Low Side Pressures, You can check the capacitor (s). You can disconnect the fan and the heat of the compressor should build some pressure. You can hit it with a rubber mallet to try to " unstick" it. You can disconnect the compressor and do a resistance check on the 3 terminals. In a normal case, I'd check the capacitor and try a hard start kit., 10 Apr 2017 ... 7:41. Go to channel · R-22 and R-410A Operating Pressures on Air Conditioners! Checking the Charge! AC Service Tech LLC•459K views · 20:22. Go ....., This is how to charge a new R-410A heat pump system in the middle of winter. An overview of the superheat process is explained and examined to see if you can..., TEMPERATURE - PRESSURE CHART FOR R-22, R-410A, R-407C, R-134A & R-404A REFRIGERANTS FYI #289 9/17/2009. updated 10/10/2012. Data points are reproduced based on available information. Advantage assumes no responsibility or liabililty for data errors. ADVANTAGE Engineering, Inc. 525 East Stop 18 Road Greenwood, IN 46142 317-887-0729 fax: 317-881 ..., Some people have low blood pressure (hypotension). It is only a problem if it causes dizziness, fainting, or shock. Learn about what can cause it. You've probably heard that high b..., -40-39-38-37-36-34-33-32-31-30-29-28-27-26-24-23-22-21-20-19-18-17-16-14-13-12-11-10-9-8-7-6-4-3-2-1: 0: 1: 2: 3: 4: 6: 7: 8: 9: 10: 11: 12: 13: 14: 16: 17: 18: 19 ..., This manual is also suitable for: View and Download Daikin R-410A technical data manual online. Outdoor units. R-410A air conditioner pdf manual download. Also for: Rxs-g2v1b., Pressure, frostbite, overexposure to vapors and deliberate inhalation are all potential hazards with most com-monly used refrigerants. In general, R-410A should be han-dled the same as R-22, with the excep-tion of the higher pressure. The 8-hour time-weighted-average "allow-able exposure level" for R-410A is the same as R-22, which is 1,000 ..., EDUS 39-605A-N. R-410A air conditioner pdf manual download. Also for: Rxyq72/96mtju, Reyq72/96mtju. ... keep distances of 10 ft. or more and use con- Nominal running cur- 4.5+4.5 duit tubes for power and transmission lines. ... in the outdoor unit to stop the additional • R-410A installations to withstand the pressure and to pre- refrigerant ..., Jun 27, 2013 · 410a low suction pressure. I injected super seal in a 410a system that had a tiny leak that I could not find. 2 years later I come across the problem of low suction pressure normal head pressure. Replaced txv and had same problem. Replaced compressor and had the same problem. Could the super seal be clogging the txv or evaporator or condenser ... , Below we list a dozen causes of high head pressure in an air conditioner or heat pump compressor motor. Of these, debris clogging or malfunctioning TXVs seem to be the most common problems. Air contamination in the refrigerant system. Air flow blocked across the condensing coil. Low condenser airflow will show up as high head pressure, normal ..., Charging a A/C system by subcooling. Determine your target subcooling. This is usually displayed on the back of the nameplate, located on your condensing unit. If not, 10-15 degrees F will get you ballpark range. With the unit running, connect your high side refrigerant gauge, to the liquid line port, or fitting., TEMPERATURE - PRESSURE CHART FOR R-22, R-410A, R-407C, R-134A & R-404A REFRIGERANTS FYI #289 9/17/2009. updated 10/10/2012. Data points are reproduced based on available information. Advantage assumes no responsibility or liabililty for data errors. ADVANTAGE Engineering, Inc. 525 East Stop 18 Road Greenwood, IN 46142 317-887-0729 fax: 317-881 ... , TEMPERATURE - PRESSURE CHART FOR R-22, R-410A, R-407C, R-134A & R-404A REFRIGERANTS FYI #289 9/17/2009. updated 10/10/2012. Data points are reproduced based on available information. Advantage assumes no responsibility or liabililty for data errors. ADVANTAGE Engineering, Inc. 525 East Stop 18 Road Greenwood, IN 46142 …